Time limit is exhausted. Please reload CAPTCHA. × eight = 56
CANTY specializes in Mud Flow Analysis as well as Drilling Mud PSA.
Name
Email address
Phone
Inquiry
Features:
• Volume Flow Analysis
• Fluid Front Detection
• Real-Time Viewing
• Lab Particle size down to 1µm
• Analysis of oil or water based mud
• Detect oil / water / solids / gas
The CANTY SolidSizer™ is a vision-based sensor used with the CANTY Vector System image processor for dry sand size measurement in a laboratory environment. The CantyVision™ Software accurately measures multiple aspects of the sand from area / perimeter / minor and major axis / etc. In comparison to a sieve which measures only minor axis the CantyVision™ software can correlate directly to a sieve so the customer does not have to change any QC documents. The SolidSizer™ can correlate within 2% of a sieve. A typical sieve analysis takes anywhere from 20-30 minutes including cleaning and setup for a 70-100 gram sample. On the SolidSizer™ that same sample takes less than 2 minutes. Also multiple screen distributions can be setup to accommodate multiple customers or areas in the process, hence eliminating the need for multiple runs on the same sand for different size distributions. After correlating to current methods of minor axis, customers find benefit in comparing minor axis to major axis and making sure the sand is round instead of needle shaped. Reduce lab time and make sure production samples are not skipped over due to lack of sample time available!
• Inline Particle size down to 1µm
The CANTY Ultratemp™ is a vision-based camera system used with the CANTY Vector System image processor to monitor temperature of the tubes inside a hydrogen reformer. The CantyVision™ Software accurately measures temperature as well as bend in the tube for complete control. In comparison to thermocouples which are costly, not reliable, and monitor only one tube, a camera system can monitor multiple tubes at the same time. The CantyVision™ software can output a signal to alarm if the tube has increased in temperature over a certain time to an operator screen, PLC, or DCS for closed loop control. The steam can then be introduced to clean the tube and avoid plugging and then switch back to the natural gas. The pyrometer is not effective for controlling the temperature in the reformer due to the time intervals in between analysis is taken. Also, not everyone measures at the same point and this could lead to a change in temperature when a change never occurred. To calibrate the system the pyrometer can be used initially. If the temperature in the tubes increase over 10°C over 10 min, a plug has a chance to take place. With the Ultratemp™ this event can be avoided completely.
Cracking furnaces are used in a variety of applications such as the production of ethylene, hydrogen, vinyl chloride monomer (VCM), and ammonia. In each of these processes, it is important to measure the the temperatures of the tubes in which the reaction is occurring. This measurement is widely known as tube metal temperatures (TMT’s). CANTY’s high temperature camera systems are installed on these furnaces to obtain video during operation. This video is fed into CANTY’s Smart Tube software to monitor TMT’s, identify hot spots, and even track the position of individual tubes as they shift over time.
CANTY manufactures high temperature camera systems that are used to measure the temperature of materials 1,000°F and higher. In this temperature range, most materials emit light in the visible spectrum due to blackbody radiation that is able to be measured to determine temperature on a visible spectrum imaging system. This allows Canty to measure temperature in applications including tube metal, refractory, metal sheets/slabs, etc…
The SHORT LOOP SAMPLER™ combines a sampling point with the INFLOW™ Particle Analyzer to deliver real-time concentration and particle size analysis of oil, water, sand, and gas. It enables operators to test multiple points with one analyzer, verify results in the lab, and continuously measure particles from 0.7 to 20,000 microns at 30 frames per second. Designed to sample from the process stream without product loss, it provides accurate PPM/PPB and size distribution for refining and drilling optimization.
Min Fluid Velocity: 3 ft/s (If lower consult factory)
Max Fluid Velocity: 15 ft/s